APC APDU10350SM power distribution unit (PDU) 48 AC outlet(s) 0U

£2,391.68 Ex VAT

50/60 Hz, 200 – 240, 346 – 415VAC, Load Capacity 17300VA

In stock

SKU: APDU10350SM Categories: , , , Tags: , , , Brand:

Description

APC APDU10350SM. PDU types: Metered, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 48 AC outlet(s), AC outlet types: C13 coupler, C15 coupler, C19 coupler, C21 coupler, Power plug: IEC 60309. Certification: CE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1. Nominal input voltage: 400 V, Maximum current: 32 A, AC input frequency: 50 – 60 Hz. Width: 56 mm, Depth: 75 mm, Height: 1780 mm

APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 17.3kW, 3PH, 415V, 30A, 530P6, 48 Outlet
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2″ wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today’s high density deployments. to enhance and standardize network connectivity across all assets in the data center. A second port is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

Additional information

Mounting

Vertical

Product Condition

Certification

CE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1

Nominal input voltage

400 V

Maximum current

32 A

Load capacity

22100 VA

Output voltage

230 V

Product colour

Black

Package weight

12.6 kg

Weight

9.6 kg

Nominal output voltage

230 V

Operating temperature (T-T)

-5 – 60 °C

Operating relative humidity (H-H)

5 – 95%

Storage temperature (T-T)

-25 – 65 °C

Storage relative humidity (H-H)

5 – 95%

PDU types

Metered, Switched

Display

LCD

Operating altitude

0 – 15240 m

Power plug

IEC 60309

AC outlets quantity

48 AC outlet(s)

AC outlet types

C13 coupler, C15 coupler, C19 coupler, C21 coupler

On/off switch

No

Type

Three-phase

Package width

262 mm

Package depth

132 mm

Package height

1980 mm

Rack capacity

0U

AC input frequency

50 – 60 Hz

Width

56 mm

Depth

75 mm

Height

1780 mm